Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Colloids Surf B Biointerfaces ; 192: 111106, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32474325

RESUMO

Solanum lycocarpum fruits contain two major glycoalkaloids (GAs), solamargine (SM) and solasonine (SS). These compounds are reported as cytotoxic. However, they have poor water solubility and low bioavailability. To overcome these disadvantages and getting an efficient formulation the current study aimed to develop, characterize, and test the effectiveness of a nanotechnology-based strategy using poly(D,L-lactide) (PLA) nanoparticles functionalized with folate as delivery system of glycoalkaloidic extract (AE) for bladder cancer therapy. The strategic of adding folic acid into nanoformulations can increase the selectivity of the compounds to the cancer cells reducing the side effects. Our results revealed the successful preparation of AE-loaded folate-targeted nanoparticles (NP-F-AE) with particle size around 177 nm, negative zeta potential, polydispersity index <0.20, and higher efficiency of encapsulation for both GAs present in the extract (>85 %). To investigate the cellular uptake, the fluorescent dye coumarin-6 was encapsulated into the nanoparticle (NP-F-C6). The cell studies showed high uptake of nanoparticles by breast (MDA-MB-231) and bladder (RT4) cancer cells, but not for normal keratinocytes cells (HaCaT) indicating the target uptake to cancer cells. The cytotoxicity of nanoparticles was evaluated on RT4 2D culture model showing 2.16-fold lower IC50 than the free AE. Furthermore, the IC50 increased on the RT4 spheroids compared to 2D model. The nanoparticles penetrated homogeneously into the urotheliumof porcine bladder. These results showed that folate-conjugated polymeric nanoparticles are potential carriers for targeted glycoalkaloidic extract delivery to bladder cancer cells.

2.
Med Biol Eng Comput ; 43(6): 751-5, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16594302

RESUMO

A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested: lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mW m(-2) with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 x 10(-2) C kg(-2) air) as measured by piezo-electric (d33) or pyro-electric coefficients.


Assuntos
Mamografia , Radiometria/instrumentação , Desenho de Equipamento , Feminino , Humanos , Modelos Teóricos , Tecnologia Radiológica/instrumentação
4.
Med Phys ; 11(6): 866-8, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6513892

RESUMO

We describe a new type of radiation dosimeter, for the diagnostic x-ray region, using a pyroelectric detector. It consists of a PZT ceramic crystal thick enough to absorb all the incident radiation at 33 keV. This pyroelectric radiation dosimeter (PERD) produces an electrical signal when exposed to a chopped beam of x-ray photons. The PERD is basically a microcalorimeter. It has the following characteristics: (1) it responds linearly to the energy fluence rate of the radiation; (2) it responds linearly to the radiation intensity for a given radiation spectrum; (3) it has excellent stability; (4) it is simple to construct and inexpensive; and (5) it is rugged.


Assuntos
Radiometria/instrumentação , Eletricidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...